Foundation Connector
All Tests are using a 3" Hydraulic Cylinder, therefore all PSI
readings on the pressure guages should be multiplied by a factor of
7.068 in order to get the true pressure applied. 7.068 is a figure that
is the area of a 3" diameter circle (the diameter of the cylinder
shaft). The formula for figuring the area of a circle is pi-r²,
where pi = 3.14159 (1.5 x 1.5 x 3.14159 = 7.068)
|
| |
|
 |
Pouring Concrete
for Foundation Connector Test
|
| |
 |
Concrete set, wall
section fastened to foundation connector
|
| |
 |
@250psi on Guage
1 minute duration
No motion, no damage
(1767lb actual press.)
|
| |
 |
@400psi on Guage
1 minute duration
No motion, no damage
(2827.2lb actual
press.)
|
| |
 |
@550psi on Guage
Fasteners fail, stud
seperation from connector
(3887.4lb actual
press.)
|
| |
 |
|
| |
|
©2007
American Hurricane House |